A. Cold water leaving the tower and the wet bulb temperature of the surrounding air
B. Hot water entering the tower and the wet bulb temperature of the surrounding air
C. Hot water entering and the cooled water leaving the cooling tower
D. None of these
Related Mcqs:
- The term “cooling range” in a cooling tower refers to the difference in the temperature of____________________?
A. Cold water leaving the tower and the wet bulb temperature of the surrounding air
B. Hot water entering the tower and the wet bulb temperature of the surrounding air
C. Hot water entering the tower and the cooled water leaving the tower
D. None of these - If the solubilities of different components (in a liquid-liquid extraction system) increase with rise in temperature, then the temperature above which they dissolve completely is known as the critical solution temperature (CST or consolute temperature). If solubilities increase with decrease in temperature, then CST is the temperature below which they dissolve completely. If a binary system has no critical solution temperature, it implies that___________________?
A. The system comprises of partially miscible liquids
B. The system comprises of miscible liquids
C. The system comprises of an azeotrope
D. On heating, a vapor phase will appear; while on cooling, a solid phase will appear - A natural draft cooling tower is filled with wooden grids, which covers about _________________ percent of the tower height?
A. 10-15
B. 30-40
C. 70-80
D. 90-100 - The cooling effect in a cooling tower can be speeded up by _______________________?
A. Increasing the air velocity and area of exposed wet surface
B. Reducing the barometric pressure
C. Reducing the humidity of the air
D. All A., B. and C. - The cooling effect in a cooling tower cannot be increased by_____________________?
A. Increasing the air velocity over the wet surfaces
B. Reducing the humidity of entering air
C. Lowering the barometric pressure
D. None of these - The temperature of water cooled in cooling tower is always _________________ temperature of entering air?
A. More than the wet bulb
B. Less than the wet bulb
C. Equal to the wet bulb
D. Equal to the dry bulb - Can a cooling tower cool water below the wet bulb temperature of inlet air ?
A. Yes
B. No
C. Yes; but height of cooling tower will be prohibitively high
D. Yes; but the air flow rate should be excessively high - In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the________________________?
A. Range is 15°F
B. Approach is 10°F
C. Both A. & B.
D. Neither A. nor B. - When the temperature and humidity of air is low, we usually use _______________ draft cooling tower?
A. Natural
B. Forced
C. Induced
D. None of these - In a moderately sized packed absorption tower, channelling (which is most severe with stacked packings) can be minimised by taking the ratio of tower diameter to packing diameter ?
A. > 4 :1
B. < 8 : 1
C. > 8:1
D. < 6:1