A. Increasing the air velocity over the wet surfaces
B. Reducing the humidity of entering air
C. Lowering the barometric pressure
D. None of these
Related Mcqs:
- The cooling effect in a cooling tower can be speeded up by _______________________?
A. Increasing the air velocity and area of exposed wet surface
B. Reducing the barometric pressure
C. Reducing the humidity of the air
D. All A., B. and C. - A natural draft cooling tower is filled with wooden grids, which covers about _________________ percent of the tower height?
A. 10-15
B. 30-40
C. 70-80
D. 90-100 - The term “cooling range” in a cooling tower refers to the difference in the temperature of____________________?
A. Cold water leaving the tower and the wet bulb temperature of the surrounding air
B. Hot water entering the tower and the wet bulb temperature of the surrounding air
C. Hot water entering the tower and the cooled water leaving the tower
D. None of these - Pressure drop through plate tower as compared to that through packed tower, for the same duty will be___________________?
A. Less
B. More
C. Equal
D. Either A. or B.; depends on the packing height - At the same gas flow rate, the pressure drop in a packed tower being irrigated with liquid _______________ that in dry packed tower ?
A. Is greater than
B. Is lower than
C. Is same as
D. Cannot be predicted as data are insufficient - In a moderately sized packed absorption tower, channelling (which is most severe with stacked packings) can be minimised by taking the ratio of tower diameter to packing diameter ?
A. > 4 :1
B. < 8 : 1
C. > 8:1
D. < 6:1 - A packed tower compared to a plate tower for a particular mass transfer operation__________________?
A. Incurs smaller pressure drop
B. Allows installation of cooling coils
C. Is less costly when built in large sizes/diameters
D. Is more suitable, if suspended solids are present in fluid streams - The term “approach” in a cooling tower refers to the difference in the temperature of the____________________?
A. Cold water leaving the tower and the wet bulb temperature of the surrounding air
B. Hot water entering the tower and the wet bulb temperature of the surrounding air
C. Hot water entering and the cooled water leaving the cooling tower
D. None of these - In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the________________________?
A. Range is 15°F
B. Approach is 10°F
C. Both A. & B.
D. Neither A. nor B. - Make up water is required in a cooling tower to replace the water lost by___________________?
A. Evaporation
B. Drift
C. Blowdown and leakage
D. All A., B. and C.