A. log P vs. T
B. log P vs. log T
C. T vs. P
D. P vs. log T
Related Mcqs:
- Cox chart is useful in the design of___________________?
A. Distillation column
B. Evaporator
C. Dryer
D. Crystalliser - Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in terms of _______________ humidity?
A. Molal
B. Relative
C. Percentage
D. None of these - Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in terms of _______________ humidity?
A. Molal
B. Relative
C. Percentage
D. None of these - If the solubilities of different components (in a liquid-liquid extraction system) increase with rise in temperature, then the temperature above which they dissolve completely is known as the critical solution temperature (CST or consolute temperature). If solubilities increase with decrease in temperature, then CST is the temperature below which they dissolve completely. If a binary system has no critical solution temperature, it implies that___________________?
A. The system comprises of partially miscible liquids
B. The system comprises of miscible liquids
C. The system comprises of an azeotrope
D. On heating, a vapor phase will appear; while on cooling, a solid phase will appear - Tray spacing in a distillation column of dia 10-12 ft. used in petroleum refinery may be around _____________ inches?
A. 5
B. 30
C. 60
D. 100 - According to the Fenske equation, what will be the minimum number of plates required in a distillation column to separate an equimolar binary mixture of components A and B into an overhead fraction containing 99 mol% A and a bottom fraction containing 98 mol% B ? Assume that relative volatility (αAB = 2) does not change appreciably in the column ?
A. 5
B. 9
C. 12
D. 28 - Packed column distillation is limited to the column _____________ metres?
A. Height < 6
B. Diameter < 0.6
C. Both A. & B.
D. Neither A. nor B. - A distillation column with N plates is being operated under normal conditions. At some point of time, the operation is shifted to total reflux condition (i.e., no product and residue are being withdrawn and feed to the column is stopped). At the new steady state ?
A. Composition of vapors and that of liquid do not vary throughout the column
B. Reboiler load and condenser load are minimum
C. The top and bottom compositions are unchanged with and without total reflux
D. The top and bottom compositions correspond to the maximum enrichment available - With decrease in the throughput (compared with the design capacity) for a bubble cap distillation column, its efficiency____________________?
A. Increases
B. Decreases
C. Remain same
D. May increase or decrease; depends on individual design - If a1 and a2 are the relative volatilities when the pressure in the distillation column is 1 and 2 atm respectively. Pick out the correct statement ?
A. a1 = a2
B. a1 = 2a2
C. a1 = 0.5 a2
D. None of these