A. lithium bromide used in vapour absorption cycle is nonvolatile
B. lithium bromide plant can’t operate below 0°C
C. a separator is used in lithium bromide plant to remove the unwanted water vapour by condensing
D. concentration of solution coming out of lithium bromide generator is more in comparison to that entering the generator
E. weak solution in liquid heat exchanger gives up heat to the strong solution
Related Mcqs:
- Pick up the correct statement about giving up of heat from one medium to other in ammonia absorption system ?
A. strong solution to weak solution
B. weak solution to strong solution
C. strong solution to ammonia vapour
D. ammonia vapour to weak solution
E. ammonia vapour to strong solution - Choose the correct statement?
A. A refrigerant should have low latent heat
B. If operating temperature of system is low, then refrigerant with low boiling point should be used
C. Precooling and subcooling bf refrigerant are same
D. Superheat and sensible heat of a. refrigerant are same
E. Refrigerant is inside the lubes in case of a direct-expansion chiller - Choose the wrong statement ?
A. Temperature of medium being cooled must be below that of the evaporator
B. Refrigerant leaves the condenser as liquid
C. All solar thermally operated absorption systems are capable only of intermittent operation
D. frost on evaporator reduces heat transfer
E. refrigerant is circulated in a refrigeration system to transfer heat - In vapor compression cycle, the condition of refrigerant is high pressure saturated liquid________________?
A. after passing through the condenser
B. before passing through the condenser
C. after passing through the expansion or thiottle valve
D. before entering the expansion valve
E. before entering the compressor - The moisture in a refrigerant is removed by___________________?
A. evaporator
B. safety relief valve
C. dehumidifier
D. driers
E. expansion valve - Domestic refrigerator working on vapour compression cycle uses the following type of expansion device____________________?
A. electrically operated throttling valve
B. manually operated valve
C. thermostatic valve
D. capillary tube
E. expansion valve. - The value of COP in vapour compression cycle is usually__________________?
A. always less than unity
B. always more than unity
C. equal to unity
D. any one of the above
E. none of the above - In vapor compression refrigeration system, refrigerant occurs as liquid between_________________?
A. condenser and expansion valve
B. compressor and evaporator
C. expansion valve and evaporator
D. compressor and condenser
E. none of the above - Short horizontal lines on pressure-enthalpy chart show__________________?
A. constant pressure lines
B. constant temperature lines
C. constant total heat lines
D. constant entropy lines
E. constant volume lines - One of the purposes of sub-cooling the liquid refrigerant is to________________?
A. reduce compressor overheating
B. reduce compressor discharge temperature
C. increase cooling effect
D. ensure that only liquid and not the vapour enters the expansion (throttling) valve
E. none of the above