A. constant pressure lines
B. constant temperature lines
C. constant total heat lines
D. constant entropy lines
E. constant volume lines
Related Mcqs:
- Vertical lines on pressure-enthalpy chart show constant_______________?
A. pressure lines
B. temperature lines
C. total heat lines
D. entropy lines
E. volume lines - The lower horizontal line of the refrigeration cycle plotted on pressure-enthalpy-diagram represents_____________________?
A. condensation of the refrigerant vapour
B. evaporation of the refrigerant liquid
C. compression of the refrigerant vapour
D. metering of the refrigerant liquid
E. none of the above - On the pressure-enthalpy diagram, condensation and desuperheating is represented by a horizontal line because the process ________________?
A. involves no change in volume
B. takes place at constant temperature
C. takes place at constant entropy
D. takes place at constant enthalpy
E. takes place at constant pressure - Allowable pressure on high-pressure side or ammonia absorption system is of the order of_________________?
A. atmospheric pressure
B. slightly above atmospheric pressure
C. 2-4 bars
D. 5-6 bars
E. 7-10 bars - A certain refrigerating system has a normal operating suction pressure of 10 kg/cm gauge and condensing pressure of about 67 kg/cm. The refrigerant used is________________?
A. Ammonia
B. Carbon dioxide
C. Freon
D. Brine
E. Hydrocarbon refrigerant - In vapor compression cycle, the condition of refrigerant is high pressure saturated liquid________________?
A. after passing through the condenser
B. before passing through the condenser
C. after passing through the expansion or thiottle valve
D. before entering the expansion valve
E. before entering the compressor - For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be____________________?
A. small
B. high
C. euqal
D. anything
E. under some conditions small and under some conditions high - For obtaining high COP, the pressure range of compressor should be_______________?
A. high
B. low
C. optimum
D. any value
E. there is no such criterion - For proper refrigeration in a cabinet, if the temperature and vapour pressure difference between cabinet and atmosphere is high, then_________________?
A. bigger cabinet should be used
B. smaller cabinet should be used
C. perfectly tight vapour seal should be used
D. refrigerant with lower evaporation temperature should be used
E. refrigerant with high boiling point must be used - Highest pressure encountered in a refrigeration system should be________________?
A. critical pressure of refrigerant
B. much below critical pressure
C. much above critical pressure
D. near critical pressure
E. there is no such restriction