A.090
B.095
C.100
D.105
Related Mcqs:
- A 200 mm thick wall made of modular bricks is 5 m long between cross walls and 3.8 m clear height between RCC slabs at top and bottom. The slenderness ratio of the wall is________________?
A. 15
B. 19
C. 20
D. 25 - If the eccentricity ratio is more than 1/24, then increase in the permissible stress in the design of wall subjected to eccentric loading as per code is_________________?
A. 10%
B. 25%
C. 33 1/3%
D. 50% - Assertion A : For eccentricity ratio exceeding 1/6, effective thickness of masonry will get reduced. Reason R : For eccentricity ratio exceeding 1/6, there will be tension on one side of the member?
Select your answer according to the codes give below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true and R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - The bending stress in a wall or column subjected to effective vertical load need not be considered, if the eccentricity ratio is_________________?
A. less than or equal to 1/24
B. less than or equal to 1/6
C. more than 1/24
D. less than or equal to 1/12 - For earthquake resistant masonry buildings, the vertical distance between openings one above the other in a load bearing wall shall not be less than_________________?
A. 50 cm
B. 60 cm
C. 75 cm
D. 100 cm - A free standing brick wall 20 cm thick is subjected to a wind pressure of 75kg/m2. The maximum height of wall from stability consideration is___________________?
A. 0.64 m
B. 0.96 m
C. 1.28 m
D. 1.5 m - The timber floor not spanning on the masonry wall but properly anchored to the wall gives________________?
A. lateral restraint but not rotational restraint
B. rotational restraint but not lateral restraint
C. both lateral and rotational restraints
D. neither lateral nor rotational restraint - If H is the height of wall between centers of supports, then the effective height of wall where concrete floors have a bearing on wall irrespective of the direction of span will be________________?
A. 0.75 H
B. 0.85 H
C. 1.0 H
D. 1.5 H - Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall. Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - If the ratio of center to center spacing of intersecting walls to actual thickness of intersecting wall is more than 20, then the stiffening coefficient for wall proper will be_________________?
A. 0
B. between 0 and 1
C. 1
D. greater than 1