A. shear
B. vertical tensile splitting
C. buckling
D. any of the above
Related Mcqs:
- Assertion A : From consideration of structural soundness and economy of design, most codes control the maximum slenderness ratio of masonry walls and columns. Reason R : By controlling the maximum slenderness ratio, failure is by excessive stress and not by buckling.?
Select your answer according to codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not .the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - Assertion A : For eccentricity ratio exceeding 1/6, effective thickness of masonry will get reduced. Reason R : For eccentricity ratio exceeding 1/6, there will be tension on one side of the member?
Select your answer according to the codes give below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true and R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - Consider the following statements regarding bands to be provided for strengthening masonry work in masonry buildings constructed in zone III, IV and V?
(i) Lintel band is provided at lintel level on partition walls,
(ii) Gable band is provided at top of gable masonry below the purlins,
(iii) The bands shall be to full width of the wall and not less than 7.5 cm in depth,
(iv) The bands shall be made of reinforced concrete only.the correct statements are?
A. (i) and (ii)
B. (i) and (iii)
C. (ii) and (iv)
D. (ii) and (iii) - For earthquake resistant masonry buildings, where seismic coefficient is less than 0.08, the horizontal distance between two openings shall not be less than_________________?
A. Vt x height of shorter opening
B. Vt x height of longer opening
C. Ax height of shorter opening
D. Vi x height of longer opening - The basic stress in masonry units having height to width ratio of 1.5 may be increased by a factor of_________________?
A. 1.2
B. 1.4
C. 1.6
D. 2.0 - For earthquake resistant masonry buildings, the vertical distance between openings one above the other in a load bearing wall shall not be less than_________________?
A. 50 cm
B. 60 cm
C. 75 cm
D. 100 cm - Water retentivity for brick masonry should not be less than__________________?
A. 50%
B. 60%
C. 70%
D. 80% - A 200 mm thick brick masonry wall made of modular bricks carries an axial load of 30 kN/m from wall above and an eccentric load of 20 kN/m from RCC floor acting at a distance of 47.5 mm from the centre line of the wall. The resultant eccentricity ratio is A. B. C. D. ?
A.090
B.095
C.100
D.105 - The timber floor not spanning on the masonry wall but properly anchored to the wall gives________________?
A. lateral restraint but not rotational restraint
B. rotational restraint but not lateral restraint
C. both lateral and rotational restraints
D. neither lateral nor rotational restraint - For masonry built in 1:1:6 cement-lime-sand mix mortar or equivalent, the horizontal shear stress permissible on the area of a mortar bed joint is_______________?
A. 0.15 MPa
B. 0.125 MPa
C. 0.1 MPa
D. 0.075 MPa